8P Oil Temperature Chiller
Brand name:DOCO
Model:DC-YL260P
Cooling capacity:24kw
Refrigerant:R22, R407, R410
Certificate:ISO, CE
Compressor brand:Copeland, Panasonic, Hitachi, Daikin
Warranty:1 Year
Application:Widely used in industries: Large Hydraulic System, Hydraulic Machine Tool, CNC Machining Center, Milling Machines, Grinding Machines, Four-Column Punching Machines etc.
Enquiry
Performance & Application
The casing of the oil chiller is designed by the 3D sheet metal software and machined by imported precision sheet metal equipment CNC with environmental electrostatic spraying, which makes the oil chiller solid, wearing well and elegant. The condenser of the oil chiller is made of thickening copper tubing and corrugated aluminum fin, which makes the oil chiller with high heat exchange efficiency and saving electricity. The world famous brand compressors, such as Panasonic, Dakin, Copeland etc., are used in oil chillers and the electric controlling components for refrigeration are also famous brands, such as Danfoss, Emerson, Siemens etc.
The oil chiller is aimed at reducing the oil temperature to prevent oil from degradation, oxidation or evaporation, keeping the oil viscosity and stabilizing the oil pressure to avoid oil shocking. All these prolong the service life of equipments or cutters and improve the machining accuracy of machine tool.
Specially, the oil chiller has a separate oil pump circulation system, through which the oil is sucked into the fuel tank, cooled by oil chiller and then sent back to fuel tank. That keeps the oil in the fuel tank constant at the setting temperature.
The oil chillers are widely used in industries: Large Hydraulic System, Hydraulic Machine Tool, CNC Machining Center, Milling Machines, Grinding Machines, Four-Column Punching Machines, Engraving Machines, the Hydraulic Pressure Station and Lubricating System of all kinds of machines.
Product Configuration
Safeguard
Technical Parameters
MODEL ITEM |
Model |
DC- YL28P |
DC- YL35P |
DC- YL55P |
DC- YL83P |
DC- YL135P |
DC- YL210P-D |
DC- YL270P-D |
DC- YL405P-T |
DC- YL540P-F |
HorsePower |
HP |
1 |
1.5 |
2 |
3 |
5 |
8 |
10 |
15 |
20 |
Cooling Capacity |
kcal/h |
2390 |
3061 |
4730 |
7086 |
11610 |
18060 |
23220 |
35260 |
46440 |
Cooling Capacity |
KW |
2.78 |
3.56 |
5.5 |
8.24 |
13.5 |
21 |
27 |
41 |
54 |
Total Input Power |
KW |
1.7 |
2.1 |
2.6 |
4.2 |
6.5 |
12.1 |
14.1 |
20.5 |
24.8 |
Compressor Power |
KW |
0.8 |
1.2 |
1.6 |
2.5 |
4 |
3*2 |
4*2 |
4*3 |
4*4 |
Temperature Range |
℃ |
10-50℃,Desired Temperature of Hydraulic Oil:30-40℃ |
Power Supply |
Power |
380V/50Hz |
Oil Pump Flow |
L/min |
20 |
25 |
25 |
32 |
50 |
80 |
100 |
150 |
200 |
Inlet/Outlet Pipe
Caliber |
Inch |
1/2 |
1/2 |
3/4 |
1 |
1 1/2 |
1 1/2 |
2 |
2-1/2 |
2-1/2 |
Refrigerant |
|
R22 ( Optional Environmental Refrigerant R407、R410) |
Condenser |
|
Air cooled condenser(copper tubing and corrugated aluminum fin, to improve the cooling efficiency20% ) |
Evaporator |
|
Stainless steel 316 plate heat exchanger/ shell and tuge exchanger |
Fan |
|
Large-flow and Low-Noise Axial Fan Motor |
Dimensions |
Length |
585 |
605 |
605 |
685 |
886 |
1206 |
1306 |
1606 |
1806 |
Wi mm m
dth m |
525 |
535 |
555 |
685 |
766 |
656 |
656 |
956 |
1106 |
Height
mm |
962 |
962 |
1080 |
1142 |
1350 |
1550 |
1650 |
1860 |
2080 |
Safety protection |
Delayed,over current,compressor over temperature,high and low pressure,over flow switch, phase
sequence,phase-missing,exhaust overheating,antifreezing. |
Technical Specifications:
1. Model number specification:e.g. HN-YL210P-D, “HN” indicates company code, “YL” indicates oil chiller, “210” indicates refrigerating capacity 210KW, “P” indicates built-in pump, “D” indicates dual system ( two compressors), “T” indicates three compressors, “F” indicates four compressors.
2. * Compressor Power: *2 indicates two compressors working and two separate cooling system.
3. Nominal cooling capacity calculated according to:Ambient temperature: 35℃. Oil inlet flow temperature: 35℃. Oil outlet flow temperature: 30℃. Oils: ISO Vg46.
4. The oil suction inlet must be connected with rigid tube, and it's necessary to install filter. Meanwhile, it's prohibited to install valve on the oil outlet.
5. The length of oil suction tube should not be more than 1.5meters; Otherwise, the diameter of oil suction inlet must be increased.
6. Working range: Oil temperature ranges from 15℃ to 50℃. Temperature difference between inlet and outlet oil is from 3℃ to 8℃. It is better to run the oil chiller while the ambient temperature at or below 42℃; Otherwise it's necessary to use high temperature models.
7. We reserve the right to revise the above information without prior notice.
The Applications
Application of Oil Chiller in Gantry Hydraulic Molding Equipment
Application of Oil Chiler in large Copper NC Lathe
Application of Oil Chiler in Metal Chip Briquetting and Metal Baling Machine Industry